| Category | Commercial | Rugged | ||
|
Level 3
Air-Cooled
|
Level 4
Conduction-Cooled
|
|||
| Part number extension |
blank
|
-C2H | -E4H | |
| Temperature | Operational (at sea level) |
0 to 55°C CFM air flow |
-40 to 70°C CFM air flow |
-40ºC to 70ºC Card edge temp. |
| Non-operational | -40 to 85°C |
-50 to 100°C
|
-50 to 100°C | |
| Vibration | Operational (Random) |
- | 0.04 g2/Hz 5Hz-100Hz: Increase 3dB/oct 100Hz-1000Hz: 0.04 g2/Hz flat 1000Hz-2000Hz: Decrease 6dB/oct |
0.1 g2/Hz 5Hz-100Hz: Increase 3dB/oct 100Hz-1000Hz: 0.1 g2/Hz flat 1000Hz-2000Hz: Decrease 6dB/oct |
| Shock | Operational | - | 20 g peak 11ms half sine |
40 g peak 11ms half sine |
| Humidity | Operational |
5-95%
non-condensing
|
Up to 95% | Up to 95% |
| Altitude | Operational | -1,500ft to 60,000 ft | -1,500ft to 60,000 ft | |
| Conformal Coat | No |
Yes | Yes | |
Download the VMETRO Rugged Policy


RSS