VMETRO Rugged Policy



The rugged policy defines the environmental specifications used in VMETRO product development. This policy applies to the following products:
Category Commercial Rugged

 
Level 3
Air-Cooled
Level 4
Conduction-Cooled
Part number extension
blank
-C2H -E4H
Temperature Operational
(at sea level)
0 to 55°C
CFM air flow
-40 to 70°C
CFM air flow
-40ºC to 70ºC
Card edge temp.
  Non-operational -40 to 85°C
-50 to 100°C
-50 to 100°C
Vibration Operational
(Random)
- 0.04 g2/Hz

5Hz-100Hz:
Increase 3dB/oct

100Hz-1000Hz:
0.04 g2/Hz flat

1000Hz-2000Hz:
Decrease 6dB/oct
0.1 g2/Hz

5Hz-100Hz:
Increase 3dB/oct

100Hz-1000Hz:
0.1 g2/Hz flat

1000Hz-2000Hz:
Decrease 6dB/oct
Shock Operational - 20 g peak
11ms half sine
40 g peak
11ms half sine
Humidity Operational
5-95%
non-condensing
Up to 95% Up to 95%
Altitude Operational   -1,500ft to 60,000 ft -1,500ft to 60,000 ft
Conformal Coat No
Yes Yes

Download the VMETRO Rugged Policy